No picture available

Ring Core Chokes: Series B82723 for Power Lines

  • LR from 0.45 to 56 mH
  • Rated voltage: 250 V AC (50/60 Hz)
  • Higher inductance or intermediate values possible upon request
  • Approx. 1% stray inductance for symmetrical interference suppression
  • Higher rated current IR available with series B82724 … B82726
No picture available

Ring Core Chokes: Series B82722 for Power Lines

  • LR from 1.2 to 47 mH
  • Rated voltage: 250 V AC (50/60 Hz)
  • Higher inductance or intermediate values possible upon request
  • Approx. 1% stray inductance for symmetrical interference suppression
  • Higher rated current IR available with series B82723 … B82726
No picture available

Ring Core Chokes: Series B82721 for Power Lines

  • LR from 0.2 to 39 mH
  • Rated voltage: 250 V AC (50/60 Hz)
  • Higher inductance or intermediate values possible upon request
  • Approx. 1% stray inductance for symmetrical interference suppression
  • Higher rated current IR available with series B82722 … B82726
  • Vertical version with lead spacing 5 x 10 mm available (B82721J*)

No picture available

D Core Chokes: Series B82731M for Power Lines

  • LR from 3.3 to 100 mH
  • Nominal voltage 250 V AC/250 V DC
  • Creepage distances and clearances > 3 mm
  • Height: 20 +0.5 mm;
    Lead spacing: 12.5 x 10 ±0.2 mm
  • Higher inductance or intermediate values possible
  • Horizontal series B82731H with height 15.5 mm max. available
  • Higher rated current IR available with series B82732R/W (IR up to 2.2 A) and
    B82734R/W (IR up to 4.6 A)
No picture available

E Core Chokes: Series B82731-T for Power Lines

  • LR from 3.3 to 100 mH
  • Nominal voltage: 250 V AC/ 250 V DC
  • Creepage distances and clearances: > 3 mm
  • Height: 21.1 mm max;
    Lead spacing: 10 x 10 ±0.2 mm
  • Higher inductance or intermediate values possible
  • Approx. 2% stray inductance for symmetrical interference suppression
No picture available

Frame Core Chokes: Series B82732F*B001
for Power Lines

  • LR from 10 to 100 mH
  • Rated voltage: 250 V AC
  • Clearance and creepage distances: > 3 mm
  • Lead spacing: 18.75 x 10.0 ±0.2 mm
  • Climatic category 40/125/56 (to IEC 60068-1)
  • Excellent differential-mode suppression
No picture available

Frame Core Chokes: Series B82733F*B001
for Power Lines

  • LR from 10 to 100 mH
  • Rated voltage: 250 V AC
  • Clearance and creepage distances: > 3 mm
  • Lead spacing: 22.5 x 20.0 ±0.2 mm
  • Climatic category 40/125/56 (to IEC 60068-1)